The BPT-003 is a specialized battery performance test equipment designed for lithium battery (pack) flammability testing. It features a 102mm test hole and auto-ignition system, simulating real-world fire scenarios to evaluate battery fire resistance. Compliant with international standards (UN 38.3, IEC 62133), it’s ideal for battery manufacturers, R&D labs, and regulatory bodies.
Öğe Hayır. :
BPT-003Minimum Sipariş Miktarı (MOQ) :
1 SetÖdeme yöntemi :
L/C, T/TFiyat :
NegotiatableÜrün oranı :
ChinaTedarik Yeteneği :
10 Set per monthKurşun zamanı :
90 DaysGeleneksel ambalaj :
PlywoodBattery Combustion Test Chamber IEC 62133 Battery Fire Resistance Test Equipment
Product introduction
The BPT-003 uses a Bunsen burner (9.5mm nozzle, 100mm length) with precise flame control (10-75±2mm height, 0-999.9s±0.1s duration) to heat samples until explosion or combustion. The octagonal aluminum mesh (12"×14"×24") ensures uniform flame exposure, while remote auto-ignition (8m range) enhances safety. Its high-temperature-resistant chamber (≥800℃) supports large battery packs (305×355×610mm test area), suitable for EV, energy storage, and consumer electronics testing.
Features
Adjustable flame height (10-75±2mm) and duration (0-999.9s±0.1s) for accurate fire resistance evaluation.
Stable Bunsen burner with high-purity LPG (self-supplied).
Safety & Design:
Remote auto-ignition (8m range) and explosion-proof glass for safe operation.
Octagonal mesh ensures uniform heat distribution, preventing localized hotspots.
Large Test Capacity:
102mm test hole and 305×355×610mm test area (EV module compatible).
High-temperature insulation (≥800℃) for extreme fire simulation.
Compliance & Integration:
Meets UN 38.3, IEC 62133, UL 2580, GB 31241 standards.
RS485 data output for remote monitoring (optional software).
International reference standards
UN 38.3 (Section 38.3.4.8, flammability test).
IEC 62133 (Part 2, fire resistance evaluation).
UL 2580 (Fire resistance test for battery packs).
GB 31241 (Portable lithium battery safety, flammability test).
Product use
Battery Manufacturers:Quality control for lithium-ion cells (EV, energy storage, consumer electronics).
R&D Labs: Battery fire behavior research (thermal runaway, flame propagation).
Regulatory Bodies: Certification testing (UN 38.3, IEC 62133 compliance).
Recycling Facilities: Assessing battery fire risk during end-of-life processing.
Test objects and inspection items
Test objects: lithium-ion batteries (cylindrical, square, soft pack), battery packs (electric vehicles, energy storage, consumer electronics).
Inspection items: fire resistance (explosion/burning time), thermal runaway extension, safety compliance (UN 38.3, IEC 62133).
Technical Parameters
Category | Specifications |
Model | BPT-003 (XB-OTS-659) |
Burner | Bunsen burner, nozzle Φ9.5mm, length 100mm (LPG, self-supplied) |
Flame Control | Height: 10-75±2mm, Duration: 0-999.9s±0.1s (auto-timing) |
Test Hole | Φ102mm (central, flame access) |
Test Area | 305×355×610mm (12"×14"×24", octagonal aluminum mesh coverage) |
Ignition | Auto-ignition (remote-controlled, 8m range) |
Chamber Material | High-temperature insulation (≥800℃ resistance), explosion-proof glass window |
Power Supply | AC220V±10%, 50Hz, power ≤1.5kW (ignition system) |
Safety Features | Remote ignition, explosion-proof glass, overheat protection (auto-shutdown) |
Data Output | RS485 (optional, for test report integration) |
Dimensions | Chamber: 800×700×1200mm (W×D×H), Weight: 150kg (stable base with wheels) |
Environmental | Operating temp: 0-40℃, Humidity: ≤85%RH (non-condensing) |
Compliance | UN 38.3, IEC 62133, UL 2580, GB 31241 |